Ansys CFX fluid analysis
(1)3-D flow analysis and performance prediction of water turbine
The fluent flow analysis software can be used to do the stimulation analysis and performance prediction for some hydroelectric generating sets which need to renovate or can’t be designed according to model. The result will be reference for instruction of type selection and structure design as a result of ensuring the performance of turbine can meet the design requirements. (The left picture shows the flow analysis of renovating runner in one power station.) |
Flow line analysis of Francis turbine runner |
(2)Finite elements temperature field analysis of generator
The temperature field of the stator
|
Temperature field of magnetic pole for the rotor |
Temperature field analysis of the air ventilation |
Temperature field of the air ventilation for the rotor and stator |